All Products
Contact Person :
HE
Phone Number :
13072134949
Energy And Environmental Metering Testing SDB Averaging Pitot-Tube Flowmeter With Wide Measurement Range 3 1 To 10 1
| 1.Applicable Pipediameter Range: | DN200~DN6000 Round Pipe And Square Pipe |
|---|---|
| 2.Accuracy Class: | Class 1.0 |
| 3.Medium Temperature: | -196°℃~600°C |
70X3 Series Explosion-Proof Water Analyzer PH ORP Conductivity / Resistivity Measurement With 24V DC Source
| 1.Measuring Parameters: | PH / ORP; Electrical Conductivity |
|---|---|
| 2. Anti-hazard Classification: | Exib ICT6 |
| 3. Levels Of Protection: | IP65 |
MFS Sanitary Type Electromagnetic Flowmeter (Flow measurements in the food, beverage, and pharmaceutical industries)
| 1. Diameter Range: | DN25~DN100 |
|---|---|
| 2.Accuracy Class: | 0.2/0.5 |
| 3. Medium Temperature: | -10℃C~150℃C |
WS3000 Sewage Continuous Monitoring System
| 1.COD: | Potassium Dichromate Spectrophotometry |
|---|---|
| 2.Ammonia Nitrogen: | Hydroicylic Acid Spectrophotometric Method |
| 3. Total Phosphorus: | Ammonium Persulfate Oxide Molybdate Spectrophotometry |
WS2100 Series Of Water Vapor Centralized Sampling And Analysis Device
| 1.: | Expert Diagnosis And Automatic Control Of Water Vapor Quality |
|---|---|
| 2.: | Automatic Closed-loop Protection Under Sample Overtemperature, Sample Flow Break And Cooling Water Flow Break |
| 3.: | Sample Water To Achieve Automatic Pressure, Temperature, Flow Rate Three Parameters Constant |
7091 Series Water Quality Analyzer (Sodium ion / silicate / phosphate / hydrazine analysis in water
| 1.Measuring Parameters: | Sodium Ion / Silica / Phosphate / Hydrazine |
|---|---|
| 2.Output Signal: | 4-20mA;RS232/485 |
| 3.Levels Of Protection: | IP65 |
70X6 Series Water Quality Analyzer(The parameters including pH / 0RP, conductivity / resistivity, dissolved oxygen,
| 1.Measuring Parameters: | PH / ORP; Dissolved Oxygen; Electrical Conductivity |
|---|---|
| 2.levels Of Protection: | IP65 |
| 3.Working Temperature: | -20~60°C |
DO Module (Displays the working status of the module power supply, communication, and channel
| 1.Channel Performance: | Type: Terminal Darlington Transistor Output; Load: Maximum Current 50 MA @ 24 VDC, Starting Voltage Not Greater Than 19.2V, Resistance Resistance From 700 To 32002 |
|---|---|
| 2.Communication Performance: | Agreement: RS-485, MODBUS RTU Extension Protocol; Rate: 691.2kbps |
| 3.Power Supply: | System: 1 W @ 24 Vdc + 10%; Site: 5 W @ 24 Vdc + 10% |
AO Module (Display the module power supply and the field equipment communication
| 1.Channel Performance: | Quantity: 8 Channels; Type: 4 ~ 20 MA Current Output; Accuracy: 4 ~ 20 MA Range: ± 0.10% |
|---|---|
| 2.Communication Performance: | Agreement: RS-485, MODBUS RTU Extension Protocol; Rate: 691.2kbps |
| 3.Power Supply: | System: 1 W @ 24 Vdc + 10%; Site: 5 W @ 24 Vdc + 10% |
Fluorescence Dissolved Oxygen Measuring Instrument (Monitoring of dissolved oxygen in sewage treatment plant;
| 1.Range: | 0.00~20.00mg/L Or 0.00~20.00ppm |
|---|---|
| 2.Display: | LCD LCD Display Date, Time, Measurement Value, Historical Trend Line, Etc., The Chinese And English Operation Menu Is Optional |
| 3.Digital Interface: | MODBUS RS232 / RS485, Profibus DP Is Optional |