Remote Pressure Transmitter With Long Term Stability Maximum Range Ratio 30 1
1. Range Ability: | PDS873G Mege Pressure: 0~40MPa PDS873A: 0~20MPa (A) |
---|---|
2.Maximum Range Ratio: | 30:1 |
3.Accuracy: | ±0.1%FS |
Energy And Environmental Metering Testing SDB Averaging Pitot-Tube Flowmeter With Wide Measurement Range 3 1 To 10 1
1.Applicable Pipediameter Range: | DN200~DN6000 Round Pipe And Square Pipe |
---|---|
2.Accuracy Class: | Class 1.0 |
3.Medium Temperature: | -196°℃~600°C |
70X3 Series Explosion-Proof Water Analyzer PH ORP Conductivity / Resistivity Measurement With 24V DC Source
1.Measuring Parameters: | PH / ORP; Electrical Conductivity |
---|---|
2. Anti-hazard Classification: | Exib ICT6 |
3. Levels Of Protection: | IP65 |
MFS Sanitary Type Electromagnetic Flowmeter (Flow measurements in the food, beverage, and pharmaceutical industries)
1. Diameter Range: | DN25~DN100 |
---|---|
2.Accuracy Class: | 0.2/0.5 |
3. Medium Temperature: | -10℃C~150℃C |
WS3000 Sewage Continuous Monitoring System
1.COD: | Potassium Dichromate Spectrophotometry |
---|---|
2.Ammonia Nitrogen: | Hydroicylic Acid Spectrophotometric Method |
3. Total Phosphorus: | Ammonium Persulfate Oxide Molybdate Spectrophotometry |
WS2100 Series Of Water Vapor Centralized Sampling And Analysis Device
1.: | Expert Diagnosis And Automatic Control Of Water Vapor Quality |
---|---|
2.: | Automatic Closed-loop Protection Under Sample Overtemperature, Sample Flow Break And Cooling Water Flow Break |
3.: | Sample Water To Achieve Automatic Pressure, Temperature, Flow Rate Three Parameters Constant |
7091 Series Water Quality Analyzer (Sodium ion / silicate / phosphate / hydrazine analysis in water
1.Measuring Parameters: | Sodium Ion / Silica / Phosphate / Hydrazine |
---|---|
2.Output Signal: | 4-20mA;RS232/485 |
3.Levels Of Protection: | IP65 |
70X6 Series Water Quality Analyzer(The parameters including pH / 0RP, conductivity / resistivity, dissolved oxygen,
1.Measuring Parameters: | PH / ORP; Dissolved Oxygen; Electrical Conductivity |
---|---|
2.levels Of Protection: | IP65 |
3.Working Temperature: | -20~60°C |
DO Module (Displays the working status of the module power supply, communication, and channel
1.Channel Performance: | Type: Terminal Darlington Transistor Output; Load: Maximum Current 50 MA @ 24 VDC, Starting Voltage Not Greater Than 19.2V, Resistance Resistance From 700 To 32002 |
---|---|
2.Communication Performance: | Agreement: RS-485, MODBUS RTU Extension Protocol; Rate: 691.2kbps |
3.Power Supply: | System: 1 W @ 24 Vdc + 10%; Site: 5 W @ 24 Vdc + 10% |
AO Module (Display the module power supply and the field equipment communication
1.Channel Performance: | Quantity: 8 Channels; Type: 4 ~ 20 MA Current Output; Accuracy: 4 ~ 20 MA Range: ± 0.10% |
---|---|
2.Communication Performance: | Agreement: RS-485, MODBUS RTU Extension Protocol; Rate: 691.2kbps |